- Most 12VHPWR connectors are rated to 9.5-10A per pin. 600W / 12V / 6 pin pairs = 8.33A. Spec requires 10% safety factor - 9.17A.

- 12VHPWR connectors are compatible with 18ga or at best 16ga cables. For 90C rated single core copper wires I've seen max allowed amperages of at most 14A for 18ga and 18A for 16ga. Less in most sources.. Near the connectors those wires are so close they can't be considered single core for purpose of heat dissipation..